Generation forecasts and energy balances
A forecast has been finalised when a corrected measurement arrives. The comparison must show the correction while preserving the original forecast.
Follow the design
Business workflow
A forecast has been finalised when a corrected measurement arrives. The comparison must show the correction while preserving the original forecast. A fictional analysis of a generation facility in fixed 15-minute intervals, with separate forecast and measurement versions.
These questions are answered by the case
- A fictional analysis of a generation facility in fixed 15-minute intervals, with separate forecast and measurement versions.
- Each comparison identifies the forecast version, measurement revision and matching time interval; later actual measurements do not change historical forecasts.
These questions remain open
- Trade execution, settlement prices, grid control and regulatory balancing-group rules.
Prepare data
The interval and input version are clear.
Produce forecasts
The forecast remains immutable.
Evaluate deviations
The deviation is reproducible.
Domain subsystems and their interactions
A forecast has been finalised when a corrected measurement arrives. The comparison must show the correction while preserving the original forecast. The domain system map connects interval assignment, input versions, forecast approval and energy balance comparison.
Forecasters select approved models and input versions. The energy balance team compares forecast and measured energy. The data quality team resolves gaps and corrections. Platform operations runs computation jobs and time-series storage. The measurement source supplies versioned measurement intervals.
Interval assignment
Assigns time series to the same time period and unit system.
Described in the designInput version
Records input provenance and revision for a run.
Described in the designForecast approval
Freezes the approved forecast version.
Described in the designEnergy balance comparison
Compares specific forecast and measurement revisions.
Described in the design
Domain responsibilities
A forecast has been finalised when a corrected measurement arrives. The comparison must show the correction while preserving the original forecast.
Assigns time series to the same time period and unit system.
Records input provenance and revision for a run.
Freezes the approved forecast version.
Compares specific forecast and measurement revisions.
Practical examples
- ENTSO-E · Electricity Market Transparency ↗
Primary source for domain terminology and scope boundaries; it does not document the provider’s internal architecture.
A fictional example design for a generation facility using fixed 15-minute intervals and separate forecast and measurement versions. Each interval spans 900 seconds, inclusive at the start and exclusive at the end; a measurement at exactly 900 seconds belongs to the next interval. All figures and test targets are illustrative assumptions.