Interfaces
How does the contract for “confirm dispensing” distinguish a repetition from a new intention?
The load profile meets the specific change request “confirm dispensing”. Its content consists of order, current prescription revision, verification record, dispensing event. An idempotency key detects the same intention after a loss of response; an aggregate version protects the changed business state. The examination document P-26 documents the examination of the specifically bound prescription revision.
Starting point Test concurrency on an individual order.
Assumptions for the example case
Own fictitious example design. A fictional documentation workflow for a single medication order whose clinical decisions have already been made, without recommendations on substances, doses or treatment. Technical feedback is marked for clarification from age 60 seconds onwards; this threshold does not provide medical clearance. All figures and test goals are illustrative assumptions.
Commands, retries and current state
Command and historical result
The key binds the full content; identical repetition provides the stored receipt.
Proposed API for this example
- POST
/medikationsauftrag/{id}/commandsConfirm dispensing
- Input
- Order, current prescription revision, verification record, dispensing event; expected aggregate version, authorized role and stable command key.
- Result
- Durably stored business result and new version; version or content conflicts produce no partial effects. An accepted external request receives an open status.
- Retry behaviour
- The key is scoped to the actor, operation and business object. After authentication, first compare the existing result and canonical content: identical content returns the stored evidence; changed content produces a conflict. Only new keys trigger validation of the current version.
- GET
/medikationsauftrag/{id}Read the current business state and reason for investigation.
- Input
- Authorised identity and business object.
- Result
- Medication order with its current version, evidence and reason for any unresolved work.
- Retry behaviour
- Repeating a read creates no business change; access is checked again.
Additional state changes
| Operation | Input | Result and protection |
|---|---|---|
| Amend the prescription | Prescriber, current version, new content revision | Before dispensing, return to draft and invalidate the old verification; after dispensing, open an investigation case. |
| Confirm verification | Verifying professional and the exact current prescription revision | Draft → reviewed; no global clearance for later revisions. |
| Documentation of the action | Documenting professional, dispensing record, actual outcome and time | Dispensed or resolved investigation case → documented; an omitted action remains explicitly recorded. |
| Cancel a work order | Prescriber, version, reason | Before dispensing → cancelled; afterwards, an investigation case with the dispensing record preserved. |
Amend the prescription
- Input
- Prescriber, current version, new content revision
- Result and protection
- Before dispensing, return to draft and invalidate the old verification; after dispensing, open an investigation case.
Confirm verification
- Input
- Verifying professional and the exact current prescription revision
- Result and protection
- Draft → reviewed; no global clearance for later revisions.
Documentation of the action
- Input
- Documenting professional, dispensing record, actual outcome and time
- Result and protection
- Dispensed or resolved investigation case → documented; an omitted action remains explicitly recorded.
Cancel a work order
- Input
- Prescriber, version, reason
- Result and protection
- Before dispensing → cancelled; afterwards, an investigation case with the dispensing record preserved.
Messages across the external boundary
- Source contract
- FHIR distinguishes orders, dispensing and administration events. The state rules of this learning case are its own limited design and not a clinical work instruction.
- System responsibility
- Dispensing is recorded with verification evidence in a local transaction. The response is lost after commit. A retry returns the same dispensing record. A prescription change received in the meantime requires domain review after dispensing and must preserve that record.
Dispensing requires the revision and verification evidence
Dispensing requires the revision and verification evidence.
Confirm dispensing can re-arrive after a lost response.
Order, current prescription revision, verification record, dispensing event must remain the same at Replay. The exercise specifies the input and expected result.
- Alternative considered
- A key stored only in volatile memory loses its evidence on restart.
- Trade-off
- The Journal for Confirm dispensing requires permanent retention and protected access.
- Reassess
- The documented retry window and journal volume determine the future archiving strategy.
Try it yourself
For identical repetition, predict the results of “confirm dispensing,” the same key with a different prescription revision, and a new key with an old version.
A hint for your attempt
Retry identity and current state require separate checks.
Compare with a possible solution
- Identical
- The saved result for medication order M-26 is returned; the effect is not repeated.
- Changed
- The same key with altered canonical content results in conflict.
- New intent with a stale version
- A new key with a stale version is rejected before any business change. The interface reloads the current state and asks the user to confirm the decision again.
Apply to your project
Which input fields make two change intentions different in your project?