System Design Atlas
Application system

Sensor monitoring with late measurements

Record room temperatures transparently, display time series and create temperature alerts that can be reviewed.

Follow the design
Temperature sensor with a rising measurement curve.

The system makes temperature data and their time reliability visible.

A building team wants to trace temperature trends and investigate sustained high room temperatures. The system continuously processes measurements, makes data gaps visible and creates alerts only from completed time windows. Actuator control, automated hazard prevention and safety-critical alarms are outside its scope.

  1. Accept and assign

    The gateway sends a measurement; the system checks the device key, assignment and current boot session.

  2. Evaluate timing

    Raw measurements form a time window of 60 seconds. The window becomes final after the defined waiting period.

  3. Review and respond

    The building team sees trends, gaps and alerts. Acknowledgement records awareness; resolution requires new, fully evaluated measurements.

Workflow with tasks and outcomes

Domain subsystems and their interactions

Sensor monitoring durably accepts device measurements, distinguishes measurement time from reception time, forms time windows and provides time series and reviewable alerts. A device gateway and a notification service sit outside the system boundary.

User interfaceDevices and building team

Devices transmit measurements through a shared gateway. The building team reads the history, identifies data gaps and acknowledges alerts.

Requests and receive feedback
Sensor monitoringDomain subsystems
  • Device assignment

    Binds device keys and individual boot sessions to the correct operator and location.

    Described in the design
  • Measurement ingestion

    Validates and stores raw measurements and detects duplicates before acknowledging acceptance.

    Described in the design
  • Evaluation by time intervals

    Forms time intervals of 60 seconds, completes them after the waiting time and identifies delayed values.

    Described in the design
  • Alert management

    Tracks temperature alerts with the applied rule version, acknowledgement and traceable resolution.

    Described in the design
  • History and operations

    Provides time series, data gaps, withheld measurements and operational metrics.

    Described in the design
The measurement platform keeps raw measurements, time-based assessments and temperature alerts separate. These are domain responsibilities; their technical allocation follows in the sixth design step.

Forms of sensor monitoring

These forms differ in what they measure and how people respond. This example covers temperature trends and reviewable alerts for buildings.

Room monitoring

A sensor measures room temperature. The team views a time series, data gaps and reviewable alerts.

Fleet monitoring

Devices are compared by building, room or device group. Device operations and platform operations need separate working views.

Maintenance-related evaluation

Additional sensor measurements can support maintenance decisions. Domain review and maintenance work remain outside this example.

Practical examples

  • Azure IoT Central ↗

    Product example: visualizes historical device telemetry and time series; no statement about the architecture of this design.

Example design with 10,000 temperature devices, one value every 10 seconds. An example of a time period ranges from 12:00 to immediately before 12:01. The evaluation will be completed at 12:03 at the earliest. The waiting time of 120 seconds after the end of the time period is an evaluation rule and not a permitted deviation of the instrument clock. Numbers and temperatures are illustrative design assumptions.