System Design Atlas

Mining operations with intermittent connectivity

01 / 10Worked example

Purpose and boundary

What responsibility does the shift work order API assume, and which evidence originates outside the system?

The initial assumptions define responsibility in this example. We follow work order A-35, device G-35 and zone information Z-35. These stable identifiers connect the technical views. A device loses its connection. Underground, completed routine work is documented locally while the shift supervisor plans a central change. The fictional scope covers offline documentation of previously authorised routine work with separate safety procedures.

Starting point A device loses its connection. Underground, a completed routine work order is recorded locally while the shift supervisor plans a change centrally.

Assumptions for the example case

A fictional example design for offline documentation of previously authorised routine work, with separate safety procedures. Zone information is marked stale from age 300 seconds; this does not authorise entry or work. All figures and test targets are illustrative assumptions.

Responsibilities and external boundary

Context · Offline work documentation

Offline zone with deviceLocal routine work
Separate safety procedureIndependent responsibility
Local device journalAn offline report records an action against the received revision and grants no authorisation.
Shift work order APIAccepts evidence against the received revision
Offline-Zone mit Gerät → Lokales GerätejournalSigned action record
Lokales Gerätejournal → Schichtauftrags-APIsynchronised sequence of events

An offline report records an action against the received revision and grants no authorisation.

A device loses its connection. Underground, completed routine work is documented locally while the shift supervisor plans a central change. Actors sit outside the boundary and the shift work order API sits inside; the local gateway is external.

The specific design scope

Example situation
A device loses its connection. Underground, a completed routine work order is recorded locally while the shift supervisor plans a change centrally.
Scope
Fictional offline documentation of previously authorised routine work, with explicitly separate safety procedures.
Excluded tasks
Safety clearance, evacuation control, autonomous machine driving and replacement of emergency communications.

Offline storage records the assigned revision

Offline storage records the assigned revision

Offline storage records the assigned revision.

A device loses its connection. Underground, a completed routine work order is recorded locally while the shift supervisor plans a change centrally.

A fictional design for offline documentation of previously authorised routine work with separate safety procedures. The exercise specifies the input and expected result.

Alternative considered
Extending the scope to safety authorisation, evacuation control, autonomous machine operation or replacement of emergency communications requires additional domain contracts.
Trade-off
The initial scope covers fictional offline documentation of previously authorised routine work with separate safety procedures.
Reassess
A need for safety authorisation, evacuation control, autonomous machine operation or replacement of emergency communications requires a new scope decision.

Try it yourself

Assign responsibility for the work order, local gateway and completion decision. Name one task outside the system boundary.

A hint for your attempt

Use the business guarantee and the explicitly limited scope.

Compare with a possible solution
Primary responsibility
The shift work order API maintains the authoritative work-order record. The shift supervisor handles business decisions; platform operations provides technical processing.
External boundary
The local gateway remains an external source of evidence. Safety authorisation, evacuation control, autonomous machine operation and replacement of emergency communications are outside the scope.

Apply to your project

Which evidence for a work order would originate outside the application in your own project?

Next, mark stale zone information visibly.