Who resolves a contradictory forecast-run state, and what evidence completes the investigation?

Operating forecast run P-33 requires responsible roles and clear completion conditions. Measurement sources write only for their assigned facilities. Forecasters approve model runs; the energy balance team confirms comparisons. Raw-data exports and corrections retain traceable justification. The operations plan connects business evidence with technical signals.

Starting point Investigate data gaps before model quality.

Assumptions for the example case

A fictional example design for a generation facility using fixed 15-minute intervals and separate forecast and measurement versions. Each interval spans 900 seconds, inclusive at the start and exclusive at the end; a measurement at exactly 900 seconds belongs to the next interval. All figures and test targets are illustrative assumptions.

Signal, responsibility and resolution

Operational roles and completion

Data quality teamMissing interval · Check source and completeness
Data quality team2 MW / 0.5 MWh · Check input and model revision
Platform operations60 s queue age · Check arrival and completion rates

Business and technical roles complete only their own evidenced part.

Measurement sources write only for their assigned facilities. Forecasters approve model runs; the energy balance team confirms comparisons. Raw-data exports and corrections retain traceable justification.

Initial operations plan

SignalResponsible roleCompletion evidence
Contradictory business stateEnergy balance teamReasoned decision with reference to the original evidence.
Missing or delayed processingPlatform operationsReprocessing returns the same evidence and clears the backlog.
Unresolved completionEnergy balance teamA new correction to actual measurements does not alter a completed forecast run; it creates a new comparison revision with provenance.

Contradictory business state

Responsible role
Energy balance team
Completion evidence
Reasoned decision with reference to the original evidence.

Missing or delayed processing

Responsible role
Platform operations
Completion evidence
Reprocessing returns the same evidence and clears the backlog.

Unresolved completion

Responsible role
Energy balance team
Completion evidence
A new correction to actual measurements does not alter a completed forecast run; it creates a new comparison revision with provenance.

Responsibility for resolving this case

Roles and evidence
The data quality team resolves gaps and unit errors. Forecasters own model approval; the energy balance team owns comparisons. Platform operations checks computation backlogs and prevents older jobs from overwriting current results.

Access and recovery

Concrete authorisations
Measurement sources write only for their assigned facilities. Forecasters approve model runs; the energy balance team confirms comparisons. Raw-data exports and corrections retain traceable justification.
Recovery
After restoring forecast run P-33, reconcile its authoritative version, command journal and external evidence. Affected new effects remain blocked during this check. Agree RTO as the maximum recovery time, RPO as acceptable data loss, retention periods and on-call roles before real operation.
Confidential content
Operational logs contain an internal reference, operation, duration and result. Original business content is stored only in the access-controlled datastore.

Correction permissions are scoped to facilities

Correction permissions are scoped to facilities

Correction permissions are scoped to facilities.

Measurement sources write only for their assigned facilities. Forecasters approve model runs; the energy balance team confirms comparisons. Raw-data exports and corrections retain traceable justification.

A new correction to actual measurements does not alter a completed forecast run; it creates a new comparison revision with provenance. The exercise specifies the input and expected result.

Alternative considered
Unrestricted operational access would mix technical repair with business decisions.
Trade-off
Business investigation requires available, explicitly named people.
Reassess
Unassigned investigation roles or excessive completion times require a revised operating agreement.

Try it yourself

Identify the responsible role and completion evidence for a business discrepancy and a technical backlog.

A hint for your attempt

Restarting a process does not replace evidence of the actual action.

Compare with a possible solution
Domain issue resolution
The energy balance team checks original evidence and documents the business decision. A new correction to actual measurements does not alter a completed forecast run; it creates a new comparison revision with provenance.
Technical processing
Platform operations checks forecast computation, reprocesses stored work and verifies that the same evidence is returned and the backlog clears. Measurement sources write only for their assigned facilities. Forecasters approve model runs; the energy balance team confirms comparisons. Raw-data exports and corrections retain traceable justification.

Apply to your project

Which open state in your project needs a domain specialist as well as technical operations?

Next, test an actual-measurement correction after approval end to end.