System Design Atlas

Building digital twin with controlled equipment actions

09 / 10Worked example

Operations and security

Recovery starts by reconciling physical effects. Which evidence permits resumption?

An old datastore snapshot may omit commands already executed.

Starting point Measure rejection reasons separately.

Assumptions for the example case

A fictional laboratory setup with a ventilation demonstrator. Local hardware limits operate independently; this example replaces neither building automation nor a safety function. All quantities, thresholds and operational targets in this design are illustrative assumptions.

Reconcile before resuming

Reconcile before resuming

Controller revisionHardware state
Operational authorisationPermit new commands
RestorePending S-42
Effect reconciliationApplied / Not Executed / Open
Completion evidenceID + revision + setpoint
Restore → ControllerrevisionRequest status
Controllerrevision → WirkungsabgleichEvidence
Wirkungsabgleich → AbschlussbelegBind exactly
Abschlussbeleg → BetriebsfreigabeRecovery

New authorisations are permitted only after reconciling every pending command with the controller revision.

Restore → compare controller revisions → reconcile open commands → reopen authorisation.

Access and recovery

Authority to approve control commands
Model maintenance may edit mappings; only building operations authorises control commands. The controller checks its own local limits even when platform authorisation is valid.
Recovery
After restoration, operations blocks new control commands until controller revisions and pending commands are reconciled. A stale backup must not repeat an old effect.

Business outcome and completion

Evidence ownership
Applied and Not executed require controller evidence; Rejected requires local validation reasons. Building operations retains responsibility for unresolved effects.

Recovery starts by reconciling physical effects.

Recovery starts by reconciling physical effects.

Block new effects until revision reconciliation.

An old datastore snapshot may omit commands already executed.

Platform operations restores data and reconciles revisions. Building operations checks pending commands against controller evidence and authorises resumption.

Alternative considered
Immediate restart can re-run old orders.
Trade-off
Restarting takes longer.
Reassess
Reliable controller history can accelerate reconciliation.

Try it yourself

Name the responsible role and evidence required to resume.

A hint for your attempt

An old datastore snapshot may omit commands already executed.

Compare with a possible solution
Operations
Platform operations restores data and reconciles revisions.
Domain completion
Building operations checks pending commands against controller evidence and authorises resumption.

Apply to your project

What is the equivalent of reconciling physical effects before recovery in your project?

Step 10: connect control limits and physical effects end to end. Which evidence establishes completion?