System Design Atlas

Sensor monitoring with late measurements

10 / 10Worked example

Final design

Does the design preserve the guarantees of AL-17 when failures occur?

The design connects D-17, M-17, W-17 and AL-17 through a traceable path. Storage forms and process boundaries follow from access patterns, load and consistency requirements; the design remains independent of specific products.

Starting point Step 9 has linked signals, responsibilities and restoration as an operational plan.

Assumptions for the example case

Example design with 10,000 temperature devices, one value every 10 seconds. An example of a time period ranges from 12:00 to immediately before 12:01. The evaluation will be completed at 12:03 at the earliest. The waiting time of 120 seconds after the end of the time period is an evaluation rule and not a permitted deviation of the instrument clock. Numbers and temperatures are illustrative design assumptions.

Decisions, tests and feedback loops along the design path

Runtime view · Durable ingestion, replayable projection and separate display

Gatewaysends QoS-transported measured values
Building teamReviews history and alerts
Notification serviceProvides communications; external delivery commitment

System boundary · Sensor monitoring

Ingestion and team APIProcess: accepts, reads history, acknowledges with access protection
Raw event logAuthoritative immutable input
ProjectorWindow, timer, rule TEMP-3
Result storeTime indexes; atomic updates to windows, alerts, checkpoints and outbox
  1. Decision: Acknowledge only after committing the raw log.
  2. Test: Duplicate, delayed value and restart do not produce a second effect.
  3. Reversal: For backlogs, revisit step 3; for rule violations, step 2.
Gateway → Ingestion: messageIngestion → Raw log: commitProjector ← Raw log: replay from checkpointProjector → Result store: window, alert, checkpoint and outbox atomicallyBuilding team → Team API: Read history / acknowledge AL-17Team API ↔ Result store: authorised reads and acknowledgementsTeam API → Building team: history and AL-17Projector → Notification service: outbox request for AL-17Notification service → Building team: notification, repetition possible
  • Gateway, Team, Notification
  • Ingestion and projector
  • Raw log, time series and result store

Ingestion acknowledges after persisting the raw log. The projector can resume from its checkpoint and updates windows and alerts idempotently.

The overall map connects ingestion, raw log, projector and result store with decisions and verification points.

The design at a glance

DecisionJustificationStill to be examined
Durable acceptance before confirmationRepetition and crash do not lose a confirmed raw value.Crash before/after commit, duplicate and payload conflict.
60 s window + 120 s processing waiting timeMakes provisional and final states explainable in this example.Timer, late marking and comparison with Watermark strategy.
Final alert at > 30 °C and ≥ 4 valuesMinimum scope and rule version make AL-17 testable.Limit, scope, acknowledged and resolved.
Raw log plus time-range queriesReplay and clarification remain possible; team queries remain targeted.Retention, real query load, backup and recovery.

Durable acceptance before confirmation

Justification
Repetition and crash do not lose a confirmed raw value.
Still to be examined
Crash before/after commit, duplicate and payload conflict.

60 s window + 120 s processing waiting time

Justification
Makes provisional and final states explainable in this example.
Still to be examined
Timer, late marking and comparison with Watermark strategy.

Final alert at > 30 °C and ≥ 4 values

Justification
Minimum scope and rule version make AL-17 testable.
Still to be examined
Limit, scope, acknowledged and resolved.

Raw log plus time-range queries

Justification
Replay and clarification remain possible; team queries remain targeted.
Still to be examined
Retention, real query load, backup and recovery.

First vertical demonstration

Normal flow
Four valid values finalize W-17; mean 30.5 °C opens AL-17 with TEMP-3.
Duplicate and conflict
Same key and same payload remain unique; different payload goes into quarantine.
Time deviation
Late remains visible without silent mutation. future-clock remains outside the window.
Recovery
The projector resumes from its checkpoint and creates no duplicate final result or alert.

Open decisions before deployment

Time limits

In the example, 120 seconds are considered to be the evaluation rule.

They explain when W-17 will be final.

Trade-off
A longer wait improves completeness and increases delay; a shorter wait increases the share of late values.
Reassess
After measurement of real delivery and device time profiles.
Retention and data protection

Define retention together with purpose, access roles and investigation requirements.

17.28 GB/day is only a technical quantity assumption.

Trade-off
Longer retention improves analysis and increases protection and cost requirements.
Reassess
Before deployment with responsible persons and protection requirements.

Terms in this step

Watermark comparison
Watermarks describe event-time progress based on the data stream. This case's simple timer finalises using processing time. Both explicitly handle delays but use different progress models.

Try it yourself

Review five parts of the design: acceptance, time rule, alert, late/future-clock and restart. State a decision, test and earlier step to revisit for each.

A hint for your attempt

Each part needs an expected result. A failed test identifies the step whose assumption needs review.

Compare with a possible solution
Acceptance
Decision: commit before acknowledgement. Test: crash before/after commit and duplicate delivery. Revisit: steps 4 and 5 for lost or duplicate acceptance. Expected: one durable M-17, no acknowledged data loss, conflicts in quarantine.
Time rule
Decision: W-17 becomes final after window end + 120 s. Test: timer and late value. Revisit: step 2 if finality is unclear. Expected: provisional before the deadline, then a stable final state; values projected too late remain late.
Alert
Decision: > 30 °C and ≥ 4 values with TEMP-3. Test: 30 °C, three values, 30.5 °C with four values. Revisit: steps 2 and 5. Expected: only the four distinct final values with 30.5 °C open AL-17; acknowledgement and data gaps do not resolve it.
Time constraints
Decision: future-clock in quarantine, late in the raw log. Test: ingest both messages. Revisit: steps 4 and 9. Expected: future-clock has no window effect; the late raw measurement remains visible with W-17 unchanged.
Recovery
Decision: checkpoint plus idempotent result update. Test: restart the projector after commit. Revisit: steps 6 and 7. Expected: one final result, one AL-17 and a consistent checkpoint.

Apply to your project

Which five pieces of evidence must your event-processing design provide before deployment?

Transfer the ten decisions into the template and highlight assumptions, responsibilities and pending measurements.

Start your own design

Choose a small case from your project. The template collects the ten design tasks and leaves space for your sketches, decisions, and open assumptions. You can edit it in your text editor or note-taking app.

Download design template (.md)
Compare the ten tasks with the example case
  1. Purpose and boundary

    What effect should your measurement system demonstrate, and which human action remains outside its scope?

    In the example: Sensor monitoring provides explainable measurement states. The building team evaluates their significance and appropriate actions for each building.

  2. Requirements

    Which rule in your system needs a minimum data count, timing and a threshold together?

    In the example: AL-17 is created only from a final W-17 with at least four valid measurements and an average above 30 °C.

  3. Scale estimates

    Which query shape and retention period determine storage for your events?

    In the example: 17.28 GB/day of normalised raw data justify retention and the time-range model. Replay peaks require a separate test profile.

  4. Interfaces

    Where does your contract distinguish acceptance, processing and visible outcome?

    In the example: An ingestion acknowledgement means the raw measurement is durably stored. It does not mean W-17 is final or AL-17 is open.

  5. Data and states

    Which data is authoritative in your system, which is derived and which merely records workflow status?

    In the example: The raw event is the traceable input. Windows and alerts are derived results with explicit versions.

  6. Overall architecture

    Which process boundary separates acceptance from replayable domain effects in your design?

    In the example: Ingestion acknowledges durably accepted data. The projector may process it again after a checkpoint and advances the derived state idempotently.

  7. Critical flow

    What is the first irreversible business effect in your critical process?

    In the example: Commit the raw log before acknowledging transport. Finalise the window before creating the alert. After restart, recognise existing effects rather than duplicating them.

  8. Bottlenecks and trade-offs

    What additional measurement in your system separates a suspected cause from a mere symptom?

    In the example: Choose a queue, cache or additional distribution from a measured symptom and its cause, not from a product mentioned by a source.

  9. Operations and security

    Which role can resolve a state in your organisation, and what evidence remains?

    In the example: Every abnormal state has a signal, responsible role and traceable resolution. Open data gaps and alerts remain visible.

  10. Final design

    Which five pieces of evidence must your event-processing design provide before deployment?

    In the example: The first end-to-end flow is: authenticate → accept durably → project replayably → finalise → explain the alert → review manually. The template records decisions and evidence for the reader's own case.