System Design Atlas

Sensor monitoring with late measurements

03 / 10Worked example

Scale estimates

Which load-test assumption must remain separate from the daily volume calculation?

10,000 devices send every 10 seconds, producing 1,000 values/s and 86,400,000 values/day. Each normalised raw record is assumed to occupy 200 bytes; indexes, replicas and protocol overhead are excluded from this calculation.

Starting point The alert rule requires raw measurements, windows and a replayable projector.

Assumptions for the example case

Example design with 10,000 temperature devices, one value every 10 seconds. An example of a time period ranges from 12:00 to immediately before 12:01. The evaluation will be completed at 12:03 at the earliest. The waiting time of 120 seconds after the end of the time period is an evaluation rule and not a permitted deviation of the instrument clock. Numbers and temperatures are illustrative design assumptions.

Size throughput, daily volume and replay separately

Illustrative scale · throughput, data volume and replay separately

10,000 EquipmentOne measurement every 10 seconds1,000 Values/s
Base load10,000 ÷ 10 s = 1,000 Values/sSizes input log and projection.
Daily volume1,000 × 86.400 = 86,400,000 Values/dayDetermines retention needs for raw data.
Raw data86,400,000 × 200 B = 17.28 GB/day30 days: 518.4 GB decimal, without indices or replicates.
Replay5000 values/sA separate test peak, independent of the daily average.
  • Throughput
  • Durable data store
  • Test profile

1,000 values/s produce 17.28 GB of normalised raw data per day. Time-range queries and retention justify separate raw-data and result stores.

Average load and replay peaks answer different architecture and testing questions.

Calculate from explicit assumptions

  1. 01

    Base load

    1000 values/s

    10,000 devices ÷ 10 s = 1,000 values/s.

    For the designThe input log and projector are checked for continuous throughput.

  2. 02

    Daily volume

    86,400,000 values/day

    1,000 × 86,400 s = 86,400,000.

    For the designRetention and time-range queries require an explicit raw-data plan.

  3. 03

    Raw data

    17.28 GB/day

    86,400,000 × 200 B = 17,280,000,000 B = 17.28 GB in decimal units.

    For the design30 days adds up to 518.4 GB before indices, replicas and protocol overhead.

  4. 04

    Replay test

    5000 values/s

    A separate assumed peak.

    For the designTests restart and backlog recovery independently of average daily load.

Derive storage requirements from access patterns

Raw event log

An append-oriented, durable store.

Deduplication, restart and later clarification need the unchanged input history.

Trade-off
Storage costs grow with retention and replication.
Reassess
Once retention, replay duration and audit requirements are defined.
Time ranges

A store supporting time-range queries over aggregated series and final windows.

The team queries D-17 over time periods, not individual transport messages.

Trade-off
Raw value and derived state must remain traceably connected.
Reassess
Once concurrent query volume and required resolution are known.

Terms in this step

retention
Deliberately established storage period. It follows from clarification, analysis, costs and protection requirements.

Try it yourself

Calculate the amount of raw data for 10,000 devices, 10 seconds and 200 bytes. Complete a test for 5,000 values/s.

A hint for your attempt

First convert values per second, then per day, then bytes into decimal gigabytes.

Compare with a possible solution
Calculation
10,000 ÷ 10 = 1,000 values/s; 1,000 × 86,400 = 86,400,000 values/day; × 200 B = 17.28 GB/day. Test: Compare number in diagram, model and text.
Replay
5,000 values/s is an independent test peak. Test: observe checkpoint lag, ingestion latency and duplicate result updates.

Apply to your project

Which query shape and retention period determine storage for your events?

Load and retry behaviour lead to concrete contracts with separate guarantees in step 4.