System Design Atlas

Water leak detection and repair orders

04 / 10Worked example

Change commands and retries

Why can't duplicate deliveries count as several minutes of measurement?

Scale alone does not ensure consistent retry behaviour. This proposed API binds the role, business object, change payload and expected state to each new intent. An idempotency key identifies the same intent after a response is lost.

Starting point Test 2,000 measurements/s as a catch-up profile.

Assumptions for the example case

This fictional worked design assumes a bounded metering zone, minute-by-minute flow readings, manual confirmation of findings and one active repair order per confirmed finding. Numbers and quality targets are illustrative test assumptions. Automatic valve control, full hydraulic simulation and drinking water quality assessment are outside scope.

Retries and new intent

Sequence keys and offline proof of work

Measurement envelopeM-111 · Sequence · Value · valid
Messumschlag → SequenzregisterIdentical / changed / new
Sequence registerscounting once or quarantine
Identical → existing recordDifferent value → quarantineOffline repair → one work record

Identical sequences and repair events act once; altered readings for the same sequence end up in quarantine.

A high reading is delivered three times. Use station and sequence as its stable identity. One measurement does not satisfy a sequence of three.

Proposed domain API contracts

  1. POST/flow-observations

    Durably accept a flow measurement.

    Input
    Authenticated M-111, sequence, measurement time, litres/min, quality and assignment version for N-111.
    Result
    One measurement per sequence; identical repetition counts once, other payload goes into quarantine.
    Retry behaviour
    An identical operation by the same authorised role on the same object, using the same key and canonical payload, returns the stored original result. A changed payload under that key is rejected. External result identifiers are durably deduplicated after authentication; new intents check the current version again.
  2. POST/leak-findings

    Confirm an investigated suspected leak.

    Input
    Control room, V-111, investigation evidence, location, justification, expected version and key.
    Result
    B-111 as a confirmed finding; a raw alarm alone does not satisfy the contract.
    Retry behaviour
    An identical operation by the same authorised role on the same object, using the same key and canonical payload, returns the stored original result. A changed payload under that key is rejected. External result identifiers are durably deduplicated after authentication; new intents check the current version again.
  3. POST/leak-findings/{id}/repair-orders

    Assign an active repair job.

    Input
    Control room, B-111, responsible field service team and key.
    Result
    R-111 or existing active assignment; parallelism does not generate a second order.
    Retry behaviour
    An identical operation by the same authorised role on the same object, using the same key and canonical payload, returns the stored original result. A changed payload under that key is rejected. External result identifiers are durably deduplicated after authentication; new intents check the current version again.
  4. POST/repair-orders/{id}/work-evidence

    Submit actual work recorded offline.

    Input
    Field service, R-111, device event, work time, action taken and evidence.
    Result
    One work record and state repariert; closure awaits post-repair inspection.
    Retry behaviour
    An identical operation by the same authorised role on the same object, using the same key and canonical payload, returns the stored original result. A changed payload under that key is rejected. External result identifiers are durably deduplicated after authentication; new intents check the current version again.
  5. POST/repair-orders/{id}/verification

    Confirm restoration based on domain evidence.

    Input
    Authorised control room, post-repair inspection period, measurement evidence, R-111 and justification.
    Result
    State abgeschlossen with reliable evidence, or nacharbeit when the finding persists.
    Retry behaviour
    An identical operation by the same authorised role on the same object, using the same key and canonical payload, returns the stored original result. A changed payload under that key is rejected. External result identifiers are durably deduplicated after authentication; new intents check the current version again.
  6. GET/repair-orders/{id}

    Read outstanding repair and post-repair inspection status.

    Input
    Control room or field service authorised for this object.
    Result
    Work evidence, measurement references, ownership and missing closure evidence.
    Retry behaviour
    Repeating a read creates no business effect; the returned current state may change between requests.

Deduplicate the sequence

Deduplicate the sequence

Use the station and sequence as a stable measurement identity.

A high value is delivered three times.

One measurement does not satisfy a sequence of three.

Alternative considered
Counting messages instead of measurements generates false alarms.
Trade-off
The device contract must guarantee sequence identity.
Reassess
Replacing the station changes its identity.

Terms in this step

Deduplicate the sequence
One measurement does not satisfy a sequence of three.

Try it yourself

A station sends the same high value three times. Count valid minute values and set the alarm.

A hint for your attempt

Use the specific entities and conditions from this step. The two solution parts distinguish the decision from its evidenced outcome.

Compare with a possible solution
First part of the solution
Station and sequence identify a measurement; three deliveries count as one value.
Second part of the solution
One high reading does not satisfy the three-reading sequence. A different payload under the same sequence is quarantined.

Apply to your project

Which corresponding assumption in your project would you check first? Consider this trigger: Replacing the station changes its identity.

Step 5 examines: assign the work order once.