Critical flow
Which condition remains open after documented repair without follow-up inspection?
Trace the failure through the architecture: Field service documents a repair offline and synchronises twice. One work record is created; the order stays in repariert until post-repair inspection provides evidence. Missing measurements after repair leave verification open rather than proving successful restoration. Durable acceptance, actual effect and response are considered separately.
Starting point Keep the time series separately and reference the finding evidence.
Assumptions for the example case
This fictional worked design assumes a bounded metering zone, minute-by-minute flow readings, manual confirmation of findings and one active repair order per confirmed finding. Numbers and quality targets are illustrative test assumptions. Automatic valve control, full hydraulic simulation and drinking water quality assessment are outside scope.
Failure point in the sequence
Offline evidence and later verification readings
The work record is stored once; B-111 remains open.
Result: One work record; state repariert until post-repair measurements verify the outcome.
Replay confirms the stored work record; the inspection worker supplies evidence, and the authorised control room confirms closure through the findings API.
Effect, response and recovery
- Specific error
- Field service documents a repair offline and synchronises twice. One work record is created; the order stays in repariert until post-repair inspection provides evidence. Missing measurements after repair leave verification open rather than proving successful restoration.
- Before and after commit
- Commit durably completes the local change. Before commit, the old state remains valid; afterwards, an identical retry returns the stored outcome. Reconcile the external effect using its existing reference.
- Retry behaviour
- The station delivers the same sequence twice: it counts once towards the three-reading sequence. A changed value under the same sequence is quarantined. A duplicate repair report creates no second post-repair inspection.
Accept offline evidence
Synchronise the work record once and keep follow-up inspection open.
Repair is recorded without connection.
Duplicate synchronisation cannot close the case without evidence of success.
- Alternative considered
- Closing on upload skips post-repair inspection.
- Trade-off
- Field service sees an intermediate status.
- Reassess
- A separate physical acceptance process is agreed upon.
Terms in this step
- Accept offline evidence
- Duplicate synchronisation cannot close the case without evidence of success.
Try it yourself
An offline repair is synchronised twice; post-repair inspection is missing. Predict the work records and status.
A hint for your attempt
Use the specific entities and conditions from this step. The two solution parts distinguish the decision from its evidenced outcome.
Compare with a possible solution
- First part of the solution
- Exactly one work record is accepted; duplicate delivery creates no second work entry.
- Second part of the solution
- The order remains in repariert. Only valid post-repair inspection permits abgeschlossen; missing measurements leave verification open.
Apply to your project
Which corresponding assumption in your project would you check first? Consider this trigger: A separate physical acceptance process is agreed upon.