08 / 10Worked example

Investigating bottlenecks

What time reference determines the usability of a measurement?

The failure sequence shows where load and retries interact. The diagnostic plan treats measured waiting time, processing duration and business conflicts separately.

Starting point Query the same command and prevent retries from adding effects.

Assumptions for the example case

A fictional design with controllable equipment and an agreed power range; 15-minute dispatch; UTC time windows; local safety limits and measured effects. Figures and quality targets are illustrative test assumptions. Protection systems, primary frequency control, market bids and evidence of specific energy-regulation compliance remain outside its scope.

Diagnose the limiting resource

Separate order backlog and reservation conflict

Order backlog100/s
Queue age and confirmation delayMeasure
Reservation conflict50 kW limit
Authoritative flexibility availabilitycheck

100 commands/s load the transmission path; 30 versus 40 kW is a domain capacity conflict.

A fresh reception time can hide an old measurement. Evaluate measurement and reception times separately. A measurement aged 30,001 ms cannot support a new commitment.

From signal to action

SignalValidationReaction
Diagnose measurement ageFresh reception time conceals old measurement.Analyse measurement time and receipt time separately.
Conflicts on the shared entityTwo dispatchers concurrently request 30 and 40 kW from 50 kW of available flexibility. In either commit order, only the first reservation succeeds; the second conflicts. A newer generation replaces an older one only after an explicit replacement decision.Count expected conflicts separately from technical errors.
Peak test profile exceededSimultaneous retrieval of 1,000 plants in 10 s = 100 orders/sReassess the time-quality assumptions if they are repeatedly missed.

Diagnose measurement age

Validation
Fresh reception time conceals old measurement.
Reaction
Analyse measurement time and receipt time separately.

Conflicts on the shared entity

Validation
Two dispatchers concurrently request 30 and 40 kW from 50 kW of available flexibility. In either commit order, only the first reservation succeeds; the second conflicts. A newer generation replaces an older one only after an explicit replacement decision.
Reaction
Count expected conflicts separately from technical errors.

Peak test profile exceeded

Validation
Simultaneous retrieval of 1,000 plants in 10 s = 100 orders/s
Reaction
Reassess the time-quality assumptions if they are repeatedly missed.

Diagnose measurement age

Diagnose measurement age

Analyse measurement time and receipt time separately.

Fresh reception time conceals old measurement.

30,001 ms old measurement does not justify a new promise.

Alternative considered
Transport latency alone does not establish measurement freshness.
Trade-off
Device clocks require verification.
Reassess
Reassess the time-quality assumptions if they are repeatedly missed.

Terms in this step

Diagnose measurement age
30,001 ms old measurement does not justify a new promise.

Try it yourself

A newly received value was measured 30,001 ms ago. Evaluate it and explain why checking reception time alone is wrong.

A hint for your attempt

Use the specific entities and conditions from this step. The two solution parts distinguish the decision from its evidenced outcome.

Compare with a possible solution
First part of the solution
It is stale for new dispatch planning and is rejected for that purpose.
Second part of the solution
Fresh reception time records transport completion; it does not make the measurement itself recent.

Apply to your project

Which corresponding assumption would you check first in your project when time quality repeatedly falls below requirements?

Step 9 examines: assign responsibility for deviations.